CGPST - 09 3325 LX EN WAL BROWN
- MSDS: CGPST
- Manufacturer: VALSPAR CORP
- Product Name: 09 3325 LX EN WAL BROWN
- National Stock Number: 8010-00N083162
Product Identification
Product ID:09 3325 LX EN WAL BROWN
MSDS Date:07/15/1994
FSC:8010
NIIN:00N083162
MSDS Number: CGPST
Responsible Party
MINNEAPOLIS, MN 55415
US
Emergency Phone: 800-228-5635
Info Phone: 612-332-7371
Cage: 13418
Contractor
Telephone: 612-332-7371/800-228-5635
Cage: 13418
Ingredients
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: 55-65%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5MG(FE)/M3FUME,B2;95
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: 1%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5MG(FE)/M3FUME,B2;95
PROPIONIC ACID, 2-METHYL-,MONOESTER WITH
CAS: 25265-77-4
RTECS: UF6000000
Fraction By Weight: 1-2%
OSHA PEL N/K
ACGIH TLV: N/K
1.79 LBS/GALLON, 214
RTECS: 9999999VO
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: HARMFUL IF INHALED. MAY AFFECT
THE BRAIN, NERVOUS SYSTEM OR RESPIRATORY SYSTEM, CAUSING DIZZINESS,
HEADACHE, NAUSEA OR RESPIRATORY TRACT IRRITATION. OVEREXPOSURE TO
INGREDIENTS IN THIS PRODUCT MAY CAUSE EYE AND SKIN IRRITATION,
BRONCHITIS OR BRONCHIAL SPASMS. CHRONIC: NONE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:ANY RESPIRATORY OR SKIN CONDITION.
First Aid
First Aid:NONE. INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE F ROM
MD . SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD .
Fire Fighting
Flash Point Method:TCC
Flash Point:205F,96C
Lower Limits:3.00%
Upper Limits:13.00%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, AND/OR WATER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . CONTAINERS EXPOSED TO FIRE SHOULD BE KEPT COOL WITH
WATER SPRAY.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE SPILLS WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. DO NOT STORE ABOVE 120 DEG F. KEEP FROM FREEZING. EMPTY
CONTAINERS MAY CONTAIN PRODUCT RESIDUE.
Other Precautions:DO NOT CUT, PUNCTURE OR WELD CONTAINERS. ALL LABEL
WARNINGS MUST BE OBSERVED UNTIL CONTAINER HAS BEEN CLEANED,
RECONDITIONED OR PROPERLY DISPOSED OF.
Exposure Controls
Respiratory Protection:WEAR APPROPRIATE, PROPERLY FITTED RESPIRATOR
(NIOSH APPROVED) AND AFTER APPLICATIONS UNLESS AIR MONITORING
VAPOR/MIST LEVELS ARE BELOW APPLICABLE LIMITS. FOLLOW RESPIRATOR
MANUFACTURES DIRECTIONS FOR RESPIRATOR USE.
Ventilation:REQUIRED WHEN SPRAYING OR APPLYING IN CONFINED AREA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . USUAL CHOTHING FOR PAINTING OPERATIONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:24.0 @ 77F
Vapor Density:7.4
Spec Gravity:1.09
Evaporation Rate & Reference:0.4 (BUTYL ACETATE = 1)
Solubility in Water:YES
Appearance and Odor:NORMAL FOR A COATINGS PRODUCT.
Percent Volatiles by Volume:72.39
Stability
Stability Indicator/Materials to Avoid:YES
AVOID WATER-REACTIVE MATERIALS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CARBON DIOXIDE/MONOXIDE.
Disposal
Waste Disposal Methods:DISPOSE IN CHEMICAL DISPOSAL AREA OR IN A MANNER
THAT COMPLIES WITH LOCAL, STATE AND FEDERAL REGULATIONS. DO NOT
INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.